Auras Technology Stocks Develop Diamond Copper Cooling for 6,000W+ AI Chips

NVDAG+0.00%

Key Takeaways

  • Auras Technology has completed proof of concept for diamond copper cooling solutions for high-power AI chips.
  • Auras Technology's existing water cooling plates handle approximately 8,000 watts, with 10-kilowatt-class two-phase solutions deployed for higher power.
  • Auras Technology noted NVIDIA will adopt Micro Channel Lid design in Rubin Ultra, with Auras having the opportunity to participate.

Auras Technology (stock code 3324) is developing diamond copper materials and Micro Channel Lid solutions as AI chip power consumption climbs toward 6,000 watts and beyond. The company has completed proof of concept for diamond copper, with inquiries from NVIDIA and ASIC customers, though material processing and high-temperature soldering reliability remain challenges. Chairman Lin Yu-shen noted that as water cooling plate fin spacing shrinks and cleanliness requirements tighten to 25 microns, cleaning time has become a production capacity bottleneck. The developments address the thermal management demands of next-generation AI processors where multiple chips in single packages create uneven heat distribution.

Auras Completes Diamond Copper Proof of Concept for High-Power AI Chips

Auras Technology has completed proof of concept for diamond copper cooling solutions, with both NVIDIA and ASIC customers making inquiries. The company stated that customers are currently in evaluation stages, and the path from proof of concept to productization requires resolving material processing difficulties and performance degradation issues after high-temperature soldering.

Water Cooling Plates Handle 8,000W with Vapor Chamber Integration

As chip thermal design power progresses toward 6,000 watts and above, Auras Technology's existing water cooling plate solutions can handle approximately 8,000 watts. For applications where multiple chips are placed in the same package creating uneven heat point distribution, the company uses water cooling plates combined with vapor chambers to first spread heat from localized hot spots before the water cooling plate removes it. For higher power applications, the company has deployed 10-kilowatt-class two-phase solutions that use refrigerant vaporization to remove heat.

Fin Spacing Shrinks to 0.10mm as Cleanliness Standards Tighten

Using NVIDIA's platform as an example, Auras Technology noted that cooling plate fin spacing has shrunk from approximately 0.15 millimeters during the H100 period to approximately 0.10 millimeters for Rubin, with subsequent designs progressing toward 0.08 to 0.06 millimeters. While denser fin arrangements improve heat exchange efficiency, narrower flow channels make residual particles more likely to affect coolant flow. The company observed that cleanliness requirements have tightened from approximately 150 microns in the past to approximately 80 microns currently, with future progression toward 50 and 25 microns. As cleanliness requirements increase, particles attached to flow channels become harder to remove, requiring longer cleaning times for the same batch of products. After water cooling plates achieve finer flow channels, production volume capacity depends on whether production lines can keep pace with required cleaning time.

Auras Positioned for NVIDIA Rubin Ultra MCL Design

Regarding Micro Channel Lid for chip packaging, the company stated that NVIDIA will adopt this design in Rubin Ultra, and Auras Technology has the opportunity to participate.

FAQ

What cooling capacity can Auras Technology's current water cooling plates achieve?

Auras Technology's existing water cooling plate solutions can handle approximately 8,000 watts. For higher power applications, the company has deployed 10-kilowatt-class two-phase solutions that use refrigerant vaporization to remove heat.

Why is cleaning time becoming a production bottleneck for Auras Technology?

As fin spacing shrinks to 0.10 millimeters and cleanliness requirements tighten from 150 microns to 80 microns with future progression toward 25 microns, particles attached to narrower flow channels become harder to remove. Chairman Lin Yu-shen noted this requires longer cleaning times for each product batch, making cleaning duration a capacity-limiting factor even after achieving finer flow channel manufacturing capability.

Disclaimer: This content is for informational purposes only and does not constitute investment advice or encourage the buying or selling of crypto assets. It is intended to provide information about industry developments and is not directly related to the services offered by Gate TR. Although information obtained from third-party sources has been carefully reviewed, Gate TR assumes no responsibility for any errors or omissions. Crypto assets involve high risks and may experience significant price fluctuations. Before making any investment decisions, you should assess your financial situation and risk tolerance, conduct your own research, and make decisions independently.